Robot Alarm Codes 5103-5114 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as adjustment welding mode error, pilot arc control exception, plasma unit or servo wire feed control exception, the teach pendant will usually display a hardware and control-level alarm in the 5103 to 5114 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 5103), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (5103-5114)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
5103Adjustment Welding Mode Point ErrorThe welding mode of the AS function is different from the welding mode of the adjustment target.Check the welding mode to be adjusted, and then execute an exception reset.
5104Pilot Arc Start ExceptionPilot arc was not closed.Check the cable connection status, and restarting regeneration can eliminate the fault.
5105Plasma Unit ExceptionAn exception occurred in the plasma fine unit.Refer to the plasma fine unit manual, eliminate the exception, and then reset the fault.
5106Pilot Arc Extinguish ExceptionPilot arc extinguished.Check the cable connection status, and restarting regeneration can eliminate the fault.
5107Pilot Arc OFF ExceptionCannot turn off the pilot arc.Check the cable connection status, and then reset the fault.
5108Pilot Arc ON ExceptionBecause cleaning is turned on, the pilot arc cannot be turned on.Turn off cleaning, and then reset the fault.
5109Servo Wire Feed Control Unit ExceptionAn exception occurred in the servo wire feed control unit.Refer to the servo wire feed control unit manual to eliminate the cause of the problem, and then reset the fault.
5110Retract Operation Execution Time Exceeded 10 SecondsTo protect the auxiliary feeding device, the retract operation was stopped.If there are many retract procedures, choose to execute after 90 seconds, and then reset the fault.
5113Cannot Set WCR Input SignalWCR input signal is not assigned.Assign the WCR input signal, and then reset the fault.
5114Arc Welding Unit Setting ExceptionTwo or more welding machine units are registered, and welding cannot be executed.Change the welding machine registration information in the unit, and then reset the fault.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.