Robot Alarm Codes 5115-5203 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as welding control exception, welding mode setting error, or sensor function execution failure, the teach pendant will usually display a hardware and control-level alarm in the 5115 to 5203 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 5115), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (5115-5203)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
5115WCR OFF Pause ExceptionWCR (Welding Current Cutoff) was not terminated within the time limit.Check the signal of “WCR OFF Wait Time” from the welding constants and welding power source, and then reset the fault.
5118Arc Start Command Error in Tool Change Setup Welding Power SourceOne mechanism recorded AS commands more than twice.Modify the task program, and then reset the fault.
5130Welding Mode Option Not SetUsed a welding mode option that has not been set.Set the welding mode option, no reset operation is required.
5131Cannot Use Welding Mode OptionThe welding mode setting is incorrect, and system memory protection prevents writing options.1. Cancel the system memory protection function; 2. Restart the system. No reset operation is required.
5132Cannot Use Specified ModeThe welding unit does not support this specified mode.Replace with a welding unit that supports this specified mode, no reset operation is required.
5133Cannot Use Welding Mode OptionThe welding mode setting is incorrect.Restore the welding mode options on the welding mode option screen, no reset operation is required.
5200Cannot Execute Sensor FunctionIncorrect usage of sensor function was detected in the teaching program.1. Record the sensor search function after the movement step; 2. After recording the movement step, use the “CheckGo” function to confirm.
5201Search Range ExceededThe robot moved outside the search range.Modify (increase) the search range or program to correct the error, no reset operation is required.
5202Search Range InsufficientThe robot detected a touch state within the minimum search range.Modify (reduce) the search range or program to correct the error, no reset operation is required.
5203Deviation Range ExceededThe robot moved outside the deviation range.Modify (increase) the deviation range or program to correct the error, no reset operation is required.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.