Troubleshooting XD600G Welder Faults: A 12-Step Guide

In daily high-intensity welding operations, if your OTC DAIHEN XD600G welding machine experiences issues such as the main power indicator being off, abnormal indicator alarms, no gas flow, or no wire feeding, please do not panic. You can directly refer to the detailed troubleshooting chart below to find the corresponding causes and countermeasures based on specific fault phenomena, quickly restoring the normal operation of your equipment.

I. Core Troubleshooting Quick Reference for XD600G

No.Fault PhenomenonCause of Fault / AbnormalityTroubleshooting Measure
1Main Power Indicator PL1 is OFF“Control Power” switch ON, fan runsIndicator PL1 faultReplace PL1 indicator
“Control Power” switch ON, fan does not runDistribution box switch or (NF) not engagedCheck the distribution box
Input side cable (U or V phase) phase loss or poor contactCheck input side cable
2Abnormal Indicator PL3 (Yellow) is ONLights up when Power Control Switch S1 is “ON”Thermal switch THP1 faultReplace thermal switch THP1
CN14 or CN15 on PCB2 not inserted properlyInsert CN14 or CN15 on PCB2 firmly into place
Torch switch faultReplace torch switch
Wire feeder control cable short circuitCheck control cable (TS)
Lights up during weldingFan FM does not runRefer to No. 3 below for troubleshooting
Abnormal temp rise in DC reactor or inside power sourceIdentify cause, stop high-load work and let cool
3Control Power Switch S1 “ON”, Fan FM Does Not RunMain power indicator PL1 is OFFRefer to No. 1 troubleshooting
Main power indicator PL1 is ONControl power switch S1 faultReplace control power switch S1
Fuse F1 blownIdentify cause and replace
Fan FM faultReplace fan FM
Circuit board (control circuit) faultReplace PCB1 or PCB2
4Switching welding method with remote S7, LED4~6 do not light upAll indicators on the control panel are OFFCN4 on PCB1 not inserted properlyInsert CN4 on PCB1 firmly into place
Switching with S7, PL4 “CO2/MAG” indicator stays ONRemote cable broken or socket has poor contactReplace cable or socket
S7 or DR1, DR2 inside remote control faultReplace remote control pendant
5Continuous Gas Leaking (Won’t Stop)Circuit board (gas control circuit) faultReplace PCB1 or PCB2
Solenoid valve SOL faultReplace solenoid valve SOL
6Torch Switch TS “ON”, no gas, fan runs, abnormal light OFFSetting S3 to “Check” still yields no gasRemote S7 not set to “CO2/MAG”Set S7 to “CO2/MAG”
Cylinder valve closed or pressure insufficientOpen valve, check pressure
Solenoid valve SOL faultReplace solenoid valve SOL
AC contactor MS faultReplace AC contactor MS
Circuit board (gas control circuit) faultCheck and replace PCB1 or PCB2
Gas flows after setting S3 to “Check”Torch switch TS faultReplace torch switch TS
Wire feeder control cable broken or poor contactCheck and replace cable or socket
7Torch Switch TS “ON”, no wire feedingNo gas flowRefer to No. 6 troubleshooting
Wire inching also failsWire feeder control cable broken or socket poor contactCheck and replace cable or socket
Fuse F2 blownIdentify cause and replace
Resistor R2 faultIdentify cause and replace
Thyristor SCR3 faultIdentify cause and replace
Wire feed motor faultCheck and repair wire feed motor
Circuit board (motor circuit) faultCheck and replace PCB1 or PCB2
8Torch Switch TS “ON”, no voltage outputNo gas flowRefer to No. 6 troubleshooting
Switching welding method also yields no output voltageCircuit board (motor circuit) faultCheck and replace PCB1 or PCB2
Thyristor SCR1, 2 faultReplace thyristor SCR1, 2
PCB2(CN4/23/24) and PCB1(CN8) not inserted properlyRe-insert connection plugs firmly
9Massive current appears, uncontrollableThyristor SCR1, 2 faultReplace thyristor SCR1, 2
Hall sensor CT faultReplace Hall sensor CT
Specified wiring open circuit or short circuitCheck related internal wiring
Circuit board (control/arc ignition circuit) faultCheck and replace PCB1 or PCB2
10Welding current and voltage unadjustableRemote cable broken or socket poor contactCheck and replace cable or socket
Remote voltage/current potentiometers R5, R6 faultReplace current/voltage potentiometers
Circuit board (control circuit) faultCheck and replace PCB1 or PCB2
11Cannot switch from slow wire feed to welding wire feed speedHall sensor CT faultReplace Hall sensor CT
Circuit board (control circuit) faultCheck and replace PCB1 or PCB2
12Cannot achieve self-hold when crater fill is setCrater fill toggle switch S5 faultCheck and replace toggle switch S5
Circuit board (control circuit) faultCheck and replace PCB1 or PCB2

Global After-Sales Service & Technical Support

As an authorized global supplier of industrial welding equipment, we are committed to providing industrial customers with efficient technical maintenance support and 100% genuine original welding machines, wire feeders, and consumable spare parts.

📞 24/7 Technical Service & Business Hotline
(WhatsApp & WeChat Same No.): +86-180-9663-1656

✉️ Email: ahojotc@gmail.com

If you encounter difficulties while troubleshooting the XD600G using the chart above, or if you need to purchase specific internal circuit boards, thyristors, or other original parts, please feel free to add our WhatsApp/WeChat for communication!

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.