Website internal page banner

Robot Alarm Codes 2204-2258 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences abnormalities such as exceeding the multi-layer queue limit, conveyor belt synchronization invalid, register/variable error, or Dynalog function command exception, the teach pendant will usually display a control-level alarm in the 2204 to 2258 range.

To help on-site engineers quickly locate problems, we have organized the diagnostic terminology from the maintenance manual to provide you with the following fault quick reference table. We recommend using the search function, entering the error code (e.g., 2204), to accurately obtain troubleshooting suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (2204-2258)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
2204Exceeded Multi-Layer Queue LimitDetected when trying to execute a multi-layer queue with more than 8 layers.Confirm the robot program, no special release is required.
2230Conveyor Belt Synchronization InvalidAttempted to execute a function related to the conveyor belt when conveyor belt synchronization cannot be performed.Enable conveyor belt synchronization, and then reset the exception.
2250Step Data ExceptionThis error is detected when a value of an application command parameter that is not allowed is set.Reset the correct parameter.
2251Incorrect Register or Variable NumberWhen an incorrect register or variable number is used in the program.Type the correct register or variable number, and then reset the exception.
2252Failed to Read or Write VariableAn error occurred when continuously reading or writing a variable.Confirm the number of the variable to be read or written, and then reset the exception.
2253Function Command Parameter Out of Normal RangeAn illegal parameter of the function command was found during regeneration operation.Please calibrate the parameter.
2254Dynalog Function Command Out of Normal RangeAn illegal function command was found during regeneration operation.Please set the correct function command again.
2255Divided by 0A numerical value is divided by 0 in the robot language file.Check the program.
2256Executing Compilation, Cannot RegenerateA regeneration command was input during the compilation process.Please start after the compilation process is completed.
2258Wrist Posture Outside Limit RangeOperated in a posture that exceeds the set limit range of the wrist posture.Operate within the limit range, and then reset the exception.

II. Get Professional Technical Support and Maintenance Services

If the robot displays a hardware-level alarm and routine reset attempts are ineffective, do not forcefully operate the arm or repeatedly force restarts, so as not to cause secondary damage.

Contact Anhui Oujie for Technical Guidance

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.