Robot Alarm Codes 2825-2851 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences abnormalities such as insufficient coating material, sealing ready timeout, analog input board not installed, or force/torque sensor failure, the teach pendant will usually display a hardware and control-level alarm in the 2825 to 2851 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage peripheral devices.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 2825), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (2825-2851)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
2825Flow Ready ExceptionThe set pressure was not reached within the time set by the constant.Confirm whether the specified pressure is appropriate, and then reset the exception.
2826Material ShortageThe sealing material in the pump is less than the specified amount.Modify the reload time, and then reset the exception.
2827Sealing Not CompletedThe robot stopped during flowing or the pump position reached the flow limit.After performing the reload operation, eliminate the cause of the stop or modify the flow time, and then reset the exception.
2828Cannot Execute Sealing OperationOther sealing operations are in progress.Modify the operation time, and then reset the exception.
2829Reload Operation Not CompletedBecause the motor is set to OFF during reloading, the reload operation cannot be completed.Modify the operation time, and then reset the exception.
2830Coating Not CompletedReached the flow limit.After performing the reload operation, modify the flow time, and then reset the exception.
2831Analog Input Board Not InstalledThe analog input board is not installed, but it is set to use the thermal sensor and pressure sensor.Modify the set values or install an analog input board, and then reset the exception.
2832Cannot Execute Coating FunctionThe specified welding gun is not defined in the device.Modify the program, and then reset the exception.
2850Executed an Unallowed Command in a Control Device With a Force/Torque SensorIn a control device with a force/torque sensor, commands other than analog input using the force/torque sensor (such as SPDDOWN) cannot be used.Modify to not use the analog input utilizing functions such as force/torque sensors in the same control device. No reset operation is required.
2851Cannot Execute Force/Torque Sensor FunctionThe force/torque sensor function is invalid.Modify the parameters, and then reset the exception.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.