During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as unstable wire feeding, ST/ZG1 parameter error, sensor stop signal input, or no SFM file, the teach pendant will usually display a hardware and control-level alarm in the 5254 to 5263 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 5254), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (5254-5263)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
5254Wire Feed UnstableThe wire feed status becomes unstable and the deviation exceeds the specified value.Check the wire feed device, and then perform an exception reset.
5255ST Parameter ErrorThe teaching parameters of the ST command exceed the setting range.Confirm whether each parameter is within the setting range, and then perform an exception reset.
5256Executed Program Without ET CommandThe ET command was not taught after the ST command.Teach the ET command, and then perform an exception reset.
5257Exception in Basic Data ParametersThe specified basic data file does not exist or the file cannot be read.Use the service menu to check the data file, and then perform an exception reset.
5258Teaching Error in ZG1 CommandThe ZG1 command cannot be executed in the weaving section.Improve teaching, and then perform an exception reset.
5259Commands Without Synchronous Teaching in Starting Point Detection/Tracking SectionIn a synchronous system, movement commands are not taught as synchronous teaching (“H”).Specify all movement commands in the specified section as synchronous teaching (“H”), and then perform an exception reset.
5260Sensor Stop Signal Is Being InputA stop signal is being input to the laser sensor.Release the emergency stop button on the laser sensor and turn off the alarm input, then exception reset.
5261Groove Not DetectedUnable to detect the groove.Ensure the LASER power is ON; ensure the cable connection between the sensor and controller is correct.
5262Welding Torch Movement Distance ExceededThe distance corrected by the sensor exceeds the internal distance.Use WinUser to adjust stability; check the cable between the control device and the laser sensor.
5263No SFM FileThe specified SFM file does not exist.Check the SFM file number, and then perform an exception reset.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.