During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as search range, position deviation, welding current and voltage exceptions, the teach pendant will usually display a hardware and control-level alarm in the 6240 to 6297 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 6240), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (6240-6297)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
6240Exceeded ZF Search RangeThe robot moved outside the search range.Modify (increase) the search range or program to correct the error, and then perform an exception reset.
6241Exceeded ZT Position Deviation RangeThe robot moved outside the position deviation range.Check the target position, modify (increase) the ZT parameter or program, and then perform an exception reset.
6242Exceeded ZN Deviation RangeThe set deviation exceeds the range.Modify (increase) the ZN deviation or program to correct the error, and then perform an exception reset.
6243Exceeded ZN Search RangeThe robot moved outside the search range during ZN.Modify (increase) the ZN search range or program to correct the error, and then perform an exception reset.
6245Exceeded Deviation RangeThe distance between the detected end point and the taught point before ZE exceeds the deviation range.Check the detected point, modify (increase) the deviation range or program, and then perform an exception reset.
6249Exceeded ZT Posture Deviation RangeThe robot moved outside the posture deviation range.Check the target posture, modify (increase) the ZT parameter or program, and then perform an exception reset.
6294Adaptive Welding Current Too HighThe welding current specified by the adaptive control exceeds the maximum current display value.Check the data table via WinUser, increase the maximum current display value for adaptive control, and then reset.
6295Adaptive Welding Current InsufficientThe welding current specified by the adaptive control is lower than the minimum current display value.Check the data table via WinUser, decrease the minimum current display value for adaptive control, and then reset.
6296Adaptive Welding Voltage Too HighThe welding voltage specified by the adaptive control exceeds the maximum voltage display value.Check the data table via WinUser, increase the maximum voltage display value for adaptive control, and then reset.
6297Adaptive Welding Voltage InsufficientThe welding voltage specified by the adaptive control is lower than the minimum voltage display value.Check the data table via WinUser, decrease the minimum voltage display value for adaptive control, and then reset.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

If you do not know how to handle such underlying alarms on-site, please take a picture of the error screen on the teach pendant and the on-site status, and send it to us via WhatsApp. As an OTC Designated Authorized Distributor, our professional maintenance engineers will provide you with a free technical assessment and troubleshooting solution!

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.