Website internal page banner

Robot Alarm Codes 6308-6334 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as angle detection, arc sensing, or wire feeding issues, the teach pendant will usually display a hardware and control-level alarm in the 6308 to 6334 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 6308), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (6308-6334)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
6308Angle 1 Too SmallThe detected angle 1 is smaller than the minimum allowable value.Check the size of angle 1, modify the allowable value if necessary, and then execute an exception reset.
6309Angle 2 Too LargeThe detected angle 2 exceeds the maximum allowable value.Check the size of angle 2, modify the allowable value if necessary, and then execute an exception reset.
6310Angle 2 Too SmallThe detected angle 2 is smaller than the minimum allowable value.Check the size of angle 2, modify the allowable value if necessary, and then execute an exception reset.
6311Groove Not DetectedFailed to detect the groove position.Check the setting parameters in the GFF file, and then execute an exception reset.
6312Unstable DirectionThis error occurs when the measured data is unstable.Check the target surface conditions and/or measurement angle, and then execute an exception reset.
6330Arc Sensor Compensation Amount Exceeds Specified ValueThe sensor compensation amount exceeds the specified value in the teaching parameters.Check the welding torch position, increase the CHASINGRANGE in the teaching parameter, or adjust the sensor.
6331Calculation Unstable During Arc SensingThe stability of arc welding decreased significantly.Correct the welding conditions to make them stable, and then execute an exception reset.
6332Cannot Detect Welding PositionDeviation detection cannot be calculated during arc sensing.Readjust the sensing parameters, and then execute an exception reset.
6333Wire Feed UnstableThe wire feed status becomes unstable and the deviation exceeds the specified value.Check the wire feed device, and then execute an exception reset.
6334ST Parameter ErrorThe teaching parameters of the ST command exceed the setting range.Confirm whether each parameter is within the setting range, and then execute an exception reset.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

If you do not know how to handle such underlying alarms on-site, please take a picture of the error screen on the teach pendant and the on-site status, and send it to us via WhatsApp. As an OTC Designated Authorized Distributor, our professional maintenance engineers will provide you with a free technical assessment and troubleshooting solution!

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.