Troubleshooting AEP300 / AEP500 Welder Faults

In daily industrial welding operations, the OTC DAIHEN AEP300 and AEP500 welding machines undertake critical welding tasks thanks to their outstanding performance. However, when the equipment encounters unexpected situations, quickly locating and resolving the issue is the key to ensuring production efficiency. If you encounter abnormalities such as failure to strike an arc, an unstable arc, or panel alarms, you can refer to the maintenance and troubleshooting methods provided in this article for a quick diagnosis.

I. AEP300 / AEP500 Basic Troubleshooting Quick Reference

For some of the most basic operational or external connection issues, please first check against the table below for preliminary confirmation:

Fault PhenomenonTroubleshooting & Inspection Points
No Arc IgnitionIs the power switch turned off?
Is there a phase loss?
Is the fuse of the input side switch blown?
Is the torch switch correctly connected, or is the wire broken? Is the workpiece cable correctly connected?
Unstable ArcAre the cable connections loose?
Is the shielding gas flow appropriate?
In AC TIG welding, is the selected cleaning width appropriate? Is the tip of the tungsten electrode rough or whitened?
Cannot Set CurrentIs the current setting toggle switch correctly selected?
When using a remote control pendant, check if it is properly connected.
Cannot Shut Off Shielding GasIs the gas check switch S4 set to the “Check” position?
No Shielding Gas OutputIs the gas supply hose correctly connected?
Is the gas volume appropriate?
Is the gas cylinder valve open?
Is the machine mistakenly set to MMA (Stick) welding mode?
Cannot Extinguish ArcIs the crater fill setting switched to “ON” or “Repeat”?
No High Frequency (HF) GeneratedIs the torch switch correctly connected, or is the wire broken?
Is the machine mistakenly set to MMA (Stick) welding mode?
Is the workpiece cable for MMA welding improperly connected?

II. AEP300 / AEP500 In-Depth Fault & Resolution Chart

If the preliminary checks fail to resolve the issue, or if the equipment indicators light up abnormally, please refer to the detailed fault list below for in-depth troubleshooting of the power source interior or circuit boards:

No.Fault PhenomenonCause of Fault / AbnormalityTroubleshooting Method
1Main Power Indicator PL1 is OFFPower switch ON, fan runsIndicator PL1 bulb faultCheck/replace indicator PL1
Power switch ON, fan does not runDistribution box switch not turned onCheck distribution box
Fuse F1 blownCheck and replace fuse F1
2Power Switch ON, Fan Does Not RunMain power indicator PL1 is OFFRefer to No. 1 troubleshooting
Main power indicator PL1 is ONFuse F1 blownReplace after finding the cause (T2, FM)
Fan faultCheck or replace fan
3Abnormal Indicator PL2 is ON After Power ONPoor connection of CN1 on PCB2Insert CN1 connector firmly in place
Insufficient water pressureRefer to No. 9 troubleshooting
Pressure switch PS faultRefer to No. 9 troubleshooting
Torch switch is in “ON” state when power is turned onTurn off the torch switch once and then turn it on
4Abnormal Indicator PL3 is ON After Power ONThermostat TH1 or TH2 faultReplace TH1 or TH2
Fan does not runReplace fan
Exceeds rated duty cycleUse within the rated duty cycle range
5No Shielding Gas Flows After Pressing Torch SwitchNo gas flows even if gas check switch S4 is set to “Check”Cylinder outlet valve is closedOpen the outlet valve
Insufficient gas pressure in cylinderCheck gas pressure
+24V power circuit fault (PL1 on PCB1 is OFF)Replace PCB1 circuit board
Solenoid valve SOL faultCheck solenoid valve SOL
Gas flows after setting gas check switch S4 to “Check”Gas control circuit faultReplace PCB2 circuit board
Control cable (2-core) broken or socket poor contactCheck wires 81, 82; replace control cable
Filter circuit faultReplace PCB3 circuit board
Abnormal indicator PL2 is ONRefer to No. 3 troubleshooting
6Cannot Shut Off Shielding GasGas check switch S4 set to “Check”Switch S4 to “Weld” mode
Gas control circuit faultReplace PCB2 circuit board
Solenoid valve SOL faultCheck solenoid valve SOL
7No High-Frequency (HF) Spark Generated Upon Switch PressSpark discharge sound is heard inside the power sourceNo shielding gas flowsRefer to No. 5 troubleshooting
Fuse F2 blownCheck and replace fuse F2
AC contactor MS faultReplace AC contactor MS
HF transformer T3 faultReplace HF transformer T3
Wire-wound resistor R6 brokenReplace wire-wound resistor R6
HF generation circuit faultReplace related PCB or grind electrode; disconnect MMA electrode holder
No spark discharge sound inside the power sourceTungsten electrode whitened/oxidizedGrind the tungsten electrode
MMA electrode holder connected to “-” terminal (HF Leakage)Correct the connection setup
8HF Generated But Fails to Strike an ArcArc appears after touching electrode to workpieceTungsten electrode whitenedGrind the tungsten electrode
Electrode too thick or current set too lowSelect correct electrode size, set correct current
Switch to MMA mode, multimeter shows no open-circuit voltageThyristor (SCR) 1, 2 faultReplace thyristors SCR1, 2
Arc ignition pulse circuit faultReplace PCB5 circuit board
Control circuit faultReplace PCB1 circuit board
9In TIG welding with “Water-Cooled Torch”, no action upon switch pressAbnormal indicator PL2 is ONInsufficient water pressure or pressure switch faultIncrease water pressure, replace pressure switch
Supply and return water connections reversedCorrect the hose connections
Abnormal indicator PL2 is OFFControl cable (2-core) broken or torch switch faultReplace control cable or torch switch
Control circuit faultReplace PCB2 circuit board
Power circuit faultReplace PCB1 circuit board
(Indicator PL1 on PCB1 is OFF)
10Welding Base Current & Pulse Current Settings InvalidInitial current, crater fill current settings also invalid (cannot set)Sequence circuit faultReplace PCB2 circuit board
Control circuit faultReplace PCB1 circuit board
Arc ignition pulse circuit faultReplace PCB5 circuit board
Initial current, crater fill current settings normalRemote pendant and jumper switch “SW2” settings inconsistentSet jumper switch “SW2” correctly per application
Remote control cable broken or poor contactCheck/replace remote control cable
Filter circuit fault when using remoteReplace PCB3 circuit board
Current setting potentiometer faultReplace potentiometer
11No Pulse Even if Pulse Switch is Set to “ON”Sequence circuit faultReplace PCB2 circuit board
12Initial Current Setting Invalid (Cannot Set)Crater fill current setting normalSequence circuit faultReplace PCB2 circuit board
Initial current potentiometer R18 faultReplace potentiometer R18
Crater fill current setting also invalidSequence circuit faultReplace PCB2 circuit board
Control circuit faultReplace PCB1 circuit board
13Crater Fill Current Setting InvalidSequence circuit faultReplace PCB2 circuit board
Control circuit faultReplace PCB1 circuit board
Arc ignition pulse circuit faultReplace PCB5 circuit board
Crater fill potentiometer R17 faultReplace potentiometer R17
14Down-Slope Time Unadjustable During Crater Fill “ON”, “Repeat”, or Spot WeldingSequence circuit faultReplace PCB2 circuit board
Down-slope potentiometer R14 faultReplace potentiometer R14
15Arc Self-Hold Fails During Crater Fill “ON”, “Repeat”, or Spot WeldingSequence circuit faultReplace PCB2 circuit board
Control circuit faultReplace PCB1 circuit board
Internal fault in Hall sensor CT1Replace CT1
16Cannot Adjust Cleaning WidthControl circuit faultReplace PCB1 circuit board
Cleaning width potentiometer R23 faultReplace potentiometer R23
17Arc Spot Welding Time UnadjustableArc spot welding time circuit faultReplace PCB2 circuit board
Spot welding time potentiometer R14 faultReplace potentiometer R14
18Hard to Strike Arc at Low Current in DC TIG WeldingFuse F3 blown in start compensation circuitCheck and replace F3
Control circuit faultReplace PCB1 circuit board
Diode DR1 or DR3 faultReplace diode DR1 or DR3
Resistor R1 or R2 faultReplace resistor R1 or R2
19Irregular High Current Surge Upon Arc IgnitionWCR detection circuit faultReplace PCB2 circuit board
Anti-surge irregular high current circuit faultReplace PCB1 circuit board
20Large Current UncontrollableThyristor SCR1, 2 faultReplace thyristors SCR1, 2
Thyristor drive circuit faultReplace PCB5 circuit board
Control circuit faultReplace PCB1 circuit board
Hall sensor CT1 faultReplace Hall sensor CT1
Current feedback circuit faultReplace PCB2 circuit board

Global After-Sales Service & Technical Support

If you need original OTC DAIHEN spare parts or remote technical guidance for specific faults, please feel free to contact our expert team. We guarantee 100% genuine original components.

📞 24/7 Technical Service & Business Hotline
(WhatsApp & WeChat Same No.): +86-180-9663-1656

✉️ Email: ahojotc@gmail.com

Welcome to add our WhatsApp/WeChat to exchange OTC AEP300 / AEP500 usage experience and get the latest equipment quotations and spare parts lists. We are dedicated to serving you!

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.