Robot Alarm Codes 5421-6006 Repair

During the operation of the OTC DAIHEN Welding Robot, if the system experiences problems such as contact detection point exception, adaptive EN ratio over limit, restart failure, or weaving trajectory exceeding the specified speed, the teach pendant will usually display a hardware and control-level alarm in the 5421 to 6006 range. If these faults are not investigated promptly, they may cause serious operational safety hazards or damage to core components such as the reducer.

To help on-site engineers and mechanics quickly locate problems, we have organized the diagnostic terminology from the official maintenance manual to provide you with the following intuitive fault quick reference table. We recommend using the search function, entering the error code (e.g., 5421), to accurately obtain troubleshooting and processing suggestions.

I. OTC Robot Alarm Code Real-Time Quick Reference Table (5421-6006)

Alarm CodeFault PhenomenonFault Cause AnalysisCountermeasures & Solutions
5421Contact Detection Point ExceptionThe final command position is too far from the detected contact signal.Contact our service department, back up the files to an external CF memory card, and turn on the control power again.
5422Adaptive EN Ratio Too LargeThe EN ratio specified by adaptive control exceeds the maximum EN ratio display value of adaptive control.Check the data table via WinUser, increase the maximum EN ratio display for adaptive control, and then reset.
5423Adaptive EN Ratio InsufficientThe EN ratio specified by adaptive control is lower than the minimum EN ratio display value of adaptive control.Check the data table via WinUser, decrease the minimum EN ratio display for adaptive control, and then reset.
5424EN Ratio Monitoring Range Setting ExceptionAn exception occurs when the minimum value of EN ratio monitoring exceeds the maximum value set in the adaptive control state.Check the minimum and maximum values of the EN ratio monitoring value, and then reset the fault.
5425Line Speed Monitoring Range Setting ExceptionAn exception occurs when the minimum value of the line speed monitoring value exceeds the maximum value set in the adaptive control state.Check the minimum and maximum values of the line speed monitoring value, and then reset the fault.
5701Option Not SetThis error occurs when using an unset option function.The option should be set, no reset operation is required.
5702Cannot RestartCannot move to the return position or restore the section status.Restart after setting the step sequence outside the section, no reset operation is required.
5703Input and Output Signals Not SetAn exception occurs when input and output signals are not set.Set the input and output signals, and then reset the fault.
6005Weaving Trajectory Exceeds Specified SpeedBecause the movement amount of the weaving pattern data is too large or the frequency (speed) is too high, the speed exceeds the specified speed.The weaving movement amount or frequency (speed) should be modified, no reset operation is required.
6006Teaching Weaving Posture Variation Exceeds LimitThe posture variation of the weaving pattern data is too large.The posture variation of the teaching weaving pattern data should be modified, no reset operation is required.

II. Get Professional Technical Support and Maintenance Services

When the robot frequently displays the above hardware-level alarms, and routine reset attempts are ineffective, do not forcefully pull the robot arm or repeatedly force restarts, so as not to cause secondary irreversible damage.

Contact Anhui Oujie for Technical Guidance

If you do not know how to handle such underlying alarms on-site, please take a picture of the error screen on the teach pendant and the on-site status, and send it to us via WhatsApp. As an OTC Designated Authorized Distributor, our professional maintenance engineers will provide you with a free technical assessment and troubleshooting solution!

Scroll to Top
Anhui Oujie Automation Technology Co., Ltd.
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.